Service Hotline: 0086-592-2229165
Products Products
Hot News / Hot News
2018 - 05 - 11
点击次数: 41
Hubgestelle von Schnupp für die Einarbeitung von Pressenwerkzeugen benötigen kein Fundament. Um die Projektlaufzeit bei vier aktuellen Maschinen zu verkürzen, simulierten die Konstrukte...
2018 - 03 - 25
点击次数: 34
Hannover/Istanbul. WIN EURASIA 2018, which ran from 15 to 18 March at the Tüyap Fair Convention and Congress Center in Istanbul, reunited for the first time in ten years six tradeshows at on...
2017 - 12 - 29
点击次数: 95
Network new and existing machines efficiently and make them transparent. The IoT Gateway software V2 from Bosch Rexroth achieves this with particular precision and cost-effectiveness.With many new fea...
2017 - 12 - 29
点击次数: 69
Although originally developed for other vehicle types, High Level Braking (HLB) is now also available for fork lift trucks.High Level Braking (HLB) saves installation space, reduces the complexity and...
2017 - 12 - 29
点击次数: 116
At SPS IPC Drives, Bosch Rexroth will present the complete spectrum of automation and electrification - from entry into the industrial IoT, to requirement-specific IPCs and intelligent drive solutions...
2017 - 12 - 29
点击次数: 79
Industry 4.0 would be inconceivable without software. The Connected Automation portfolio from Bosch Rexroth demonstrates its full potential in terms of connectivity and time-to-market.With innovations...
Contact us
联系我们
Phone: 0086-592-2229165 
Mailbox: info@sdmhyd.com
Address: Room 801 1st building No993 Anling Road Huli district, Xiamen City, Fujian Province, China  
Products 产品中心
产品列表
GeneralComponent series2XDesignPlug-in connectorElectricOperating voltagenominalUV24Lower limit valueUB(t)minV21.6Upper limit valueUB(t)maxV28.8Ripple%Control voltageONUV10…35 (I ≤ 3 mA)OFFUV0…6Maximum switching frequencyfHz4Maximum solenoid currentImaxA2Output voltageUmaxU+ - 0.2 V (typical at 2 A)Sonstige AngabenConnection to the solenoidStandardEN 175301-803Connection cross-sectionS4 x 1.5 mm2, fitting PG 11AnschlussartCable gland and screw terminalsCable diameterdmm4…10Ambient temperature rangeϑ°C-25 …  70Storage temperature rangeϑ°C-25 …  70Weightmg45
GeneralComponent series1XType of electronicsAnalogDesignModulVoltage supplyOperating voltagenominalUV24Lower limit valueUB(t)minV21Upper limit valueUB(t)maxV35Power consumptionPVA8Current consumptionmax.ImaxA0.3FuseThermal overload protection (with restart if the value falls below the temperature threshold)Analog inputsCommand valueVoltageDifferential inputUV 0±10Input resistanceRkΩ≥ 20Digital inputsController change-over 1)UV+24 (with J13); 0 (with J12)Backup relay 1)UV+24 (with J13); 0 (with J12)1)RE = 700 Ω (relay)Solenoid outputsSolenoid currentmaxImaxmA60Dither signalfHz340 ±5 % (I = 0 ... 6 mA, 3 mA pre-set)Adjustment optionsSetting rangeSolenoid current%± 10Measuring so...
GeneralComponent series1XMaterial numberData sheet1819929079Type of electronicsAnalogDesignEuro-cardVoltage supplyOperating voltagenominalUV24Lower limit valueUB(t)minV21Upper limit valueUB(t)maxV40Ripple%Power consumptionPVA35Current consumptionmax.ImaxA1.51)In case of ripple  10 %, an upstream smoothing capacitor is required (recommendation: capacitor module VT 11110)Analog inputsCommand value sourcePotentiometer 1 kΩ supplied with 10 V internal reference voltage, external signal sourceCommand valueVoltageDifferential inputUV 0 ... ±10Input resistanceRkΩ≥ 100grounded on one side, first inputUcommandV 0±10grounded on one side, second inputUcommandV 0±10Actual value valveVoltageUV10.2 (7.8 kHz)External ram...
GeneralComponent series1XType of electronicsDigitalDesignEuro-card formatVoltage supplyOperating voltagenominalUV24Lower limit valueUB(t)minV21Upper limit valueUB(t)maxV30Current consumptionmax.ImaxA3.5Analog inputsVoltageNumber and designation7 (AI1 ... AI7)Command valueVoltageDifferential input 1UV 0 ... ±10Differential input 2UV 0+10Input resistanceRkΩ100VoltageResolution for 0...10UmV5Resolution for ± 10UmV2.5Non-linearityUmV10CurrentNumber and designation4 (AI2, AI4, AI5, AI6)Command valueCurrentImA4 … 20Input resistanceRΩ100 1)CurrentResolutionIμA5Leakage currentI0.15 (with 500 Ω between port AI x - and 0 V)1)Voltage drop at actual pressure value input with 4 mA approx. 1.7 V, wit...
Position transducerCable lengthL50 m at 100 pF/mSupplementary informationReference voltagePotentiometer supplyUV10 (Imax = 50 mA)Special featuresShort-circuit-proof outputs, cable break detection for actual value line, position control with PID behavior, fast energization and fast deletion for short actuating timesAnschlussart32-pin male connector, DIN 41612, form FAmbient temperature rangeϑ°C 0 70Storage temperature rangeϑ°C-20 …  70Weightmkg0.37AnzeigenLED displayGreen 1EnableYellow 1Cable break actual valueRedUB too lowAdjustment optionsZero point calibration%± 10Range sensitivity adjustmentSetting condition%50 ... 100Solenoid outputsSolenoid currentmax.ImaxA2.7PowerPVA25Solenoid outputother proper...
GeneralComponent series1XMaterial numberData sheet1819929085Type of electronicsAnalogDesignModulVoltage supplyOperating voltagenominalUV24Lower limit valueUB(t)minV21Upper limit valueUB(t)maxV40Power consumptionmax.SmaxVA30Current consumptionmax.ImaxA1.25Analog inputsCommand value sourcePotentiometer 10 kΩ supplied with 10 V internal reference voltage, external signal sourceCommand valueVoltage (differential input)UV 0 ...  10Voltage (differential input)Input resistanceRkΩ≥ 100Digital inputsRamp switch-offUV6 ... 40Solenoid outputsSolenoid currentmax.ImaxA0.8Solenoid outputPowerSmaxVA25Solenoid outputother propertiesClocked current controllerCable lengthfor 1.5 mm2Lm20for 2.5 mm2Lm50Adjustment optionsZero point calibration informationSet with...
GeneralComponent series1XType of electronicsAnalogDesignPlug-in connectorVoltage supplyOperating voltagenominalUV24Lower limit valueUB(t)minV18Upper limit valueUB(t)maxV35Cable inductance 1)max.LmaxµH100Power consumptionmax.SmaxVA40Current consumptionmax.ImaxA1.7Fuse2 A time-lag1)Usually corresponds to a line length Analog inputsCommand valueVoltage (differential input)UV 0 ...  10for the switching function of the proportional amplifier12 ... UBVoltage (differential input)Input resistanceRkΩ≥ 20Solenoid outputsCoil inductivitymin.LminmH15Pilot currentFactory settingIvmA100Solenoid currentFactory settingIA1.6Coil resistance at 20°CR(20)Ω5.5Clock frequencyat ImaxfHz340Adjustment optionsSetting rangePilot currentIBmA0 ... 300Solenoid...
For applications outside these parameters, please consult us!Mating connectorShort designationZ4DesignAAmbient temperatureStandard°C-30 … +90Protection class according to DIN EN 60529IP 65 with mating connector mounted and fittedNumber of poles2 + PETerminal area for lines with external diametermm5 … 10Wire cross-section, max.mm²1.5 AnschlussartScrew connectionStandardEN 175301-803Certification/conformityVDE, SEV, RoHSDerating, max.16 A°C409,5 A°C601)2.5 mm2 with special wire end ferrule clamp (e. g. Knipex 975314 or Weidmüller PZ 6/5)
Operating voltageOperating voltageNominal valueUB24 VDCMaximum valueU(t)max30 V at 0 °C ≤ ϑU ≤ 40 °C 1)Minimum valueU(t)min18 V at 0 °C ≤ ϑU ≤ 40 °C 1)Reverse polarity protectionyesPower consumptionPVACurrent consumptionIAFuse/short-circuit protection1 or 2 fuses for the solenoid currents, not exchangeableI1.25 A fast-acting (SMD)Display LEDs (green)OKIs illuminated if the self-test has been completed, the relays have operated and there is no errorpowerIs illuminated if the internal power supply unit works1)see also derating characteristic curve on page 7InputsCommand value differential inputU0 … +10 V or 0 … ±10 V, RE = 100 kΩReset inputLowUR0 … ...
GeneralType / versionVT-SVT-1VT-SVTNT-2VT-SVTK-1VT-SVTK-2VT-SVTK-3Component series1X1X/G121XOperating voltageType / versionVT-SVT-1VT-SVTNT-2VT-SVTK-1VT-SVTK-2VT-SVTK-3Operating voltageU100 to 240 VAC, 50 to 60 HzOperating voltageBattery operationUB9 V 1)Power supply unit operationUB12 V DC ± 5 %Current consumption of the test deviceImA20 2)Current consumptionI0.4 A with 100 VACOutput voltageU12 VDC; 1, 25 A1)E block, not included in the scope of delivery2)additional valve flowOther informationType / versionVT-SVT-1VT-SVTNT-2VT-SVTK-1VT-SVTK-2VT-SVTK-3Fuse, secondary sideI5 APortFor valveMating connector according to DIN 43563-BF6-3/Pg11 (serial connection)Mating connector VG 95328 (serial connection)Mating con...
Type / versionVT-NE30VT-NE31…_Ausgang-1VT-NE31…_Ausgang-2Component series2X1XOperating voltageType / versionVT-NE30VT-NE31…_Ausgang-1VT-NE31…_Ausgang-2smoothedOperating voltageU230 VAC ±10 % of 115 VAC ±10 %Output voltage (with U = 230 VAC)Running emptyUO+32 VDC 1)+27 VDC 1)–27 VDC 1)Full loadUO+26 VDC 1)+24 VDC 1)–24 VDC 1)FrequencyfHz5060Output powerPOW1086Load current, max.ImaxA40.251)With a variation of ±10% from the operating voltage U = 230 VAC, the output voltage UA changes by ±10%.Other informationType / versionVT-NE30VT-NE31…_Ausgang-1VT-NE31…_Ausgang-2smoothedResidual ripple under full loadUeff%FuseIS8 A time-lag0.8 A time-lagAmbient temperature rangeϑ...
GeneralComponent series3XOther informationTerminal voltage according to VDE 0110 C, max.UVDC30Connection cross-sectionAWG (according to EN 60204, part 1)24 to 12Anschlussart64-pin female multipoint connector, DIN 41612, design GPin assignmenteven lines f/d/b/zAmbient temperature rangeϑ°C-20 … +70Type of protection according to EN 60529IP 20Weightmkg1.25
GeneralComponent series 1)3X1)One-axis versionElectronicsOperating voltage 1)U±15 VDCCurrent consumptionImA30Control outputOutput voltage, maximumUV± 10Output current, maximumImA± 5Contact load, resistive2 A, max. 30 VDCFuseIS2 A medium time-lag1)±1 % stabilizedMechanicsDeflection angle 1)ɑ20° from spring-centered mid position to end positionOperating forceInitial valueFN6End valueFN101)In case of confirmation in X directionOther characteristicsType of protection according to EN 60529above the installation levelSee ordering codebelow the installation levelIP65Cable lengthlmm600Ambient temperature rangeϑ°C-25 … +70Weightmkg1.5
GeneralNominal voltageU12 VSensor operating voltageU4.5 … 20 VMaximum current consumptionImaxmA16.8Sensor current, minimumILow7 mA; ±20 %Sensor current, maximumIHigh14 mA; ±20 %Signal ratio sensor current max./min.≥ 1.9Signal frequencyf1 … 5000 HzDirection of rotation signal 1)PWM signalElectro-magnetic compatibilityStrip line (DIN 11452-5) 1 MHz - 400 MHzV/m200Free field (DIN 11452-5) 200 MHz - 1 GHzV/m150Overvoltage protection24 V, 10 x 5 minReverse polarity resistance, reverse polarity currentProvide 195 mAprotective circuit in the control unit or externally, accordingly!Noise test according to DIN EN 60068-2-640.05 g2 ...
TypeComponent series3XGeneralWeightmkg1Installation positionanyAmbient temperature ranges (NBR seals)ϑ°C-30 … +50Conformity/certificationCEEN 61058-1:1993, IEC 60947-5-1HydraulischPressure ratingpbar2563100200400Max. operating pressure 1)pbar3070110210420Switching pressure differentialpbar122.557.5Pressure adjustment range (decreasing)pbar8 … 254 … 636 … 10010 … 20020 … 400Pressure adjustment range (increasing)pbar2,5 … 266 … 668,5 … 102,515 … 20527,5 … 407,5Hydraulic fluid temperature range (NBR seals)ϑ°C-30 … +80Viscosity rangeμmm²/s10 … 800Maximum admissible degree of contamination of the hydraulic fluid 2)Class 20/18/15 acc...
GeneralWeightmkg0.26Installation positionanyAmbient temperature rangeϑ°C-25 … +80Storage temperature rangeϑ°C-40 … +100Sine test according to DIN EN 60068-2-6:1996-0510 ... 2000 Hz, max. 20 g, 10 double cyclesTransport shock according to DIN EN 60068-2-27:1995-03Half-sine 50 g / 11 ms,3 x in positive direction,3 x negative direction (a total of 18 single shocks)Noise test according to DIN EN 60068-2-64: 1995-0820...2000 Hz, 10 gRMS, 24 hConformityCEDIN EN 60947-1: 2007 / A1: 2011 / A2: 2014DIN EN 60947-5-1: 2004 / A1: 2009DIN EN 61058-1: 2002 / A2: 2008DIN EN 60529: 1991 / A2: 2013ULUL, 508 17th edition File No E223220 (up to 350 bar)Protection class a...
GeneralComponent series1XType of electronicsDigitalDesignEuro-card formatVoltage supplyOperating voltagenominalUV24Lower limit valueUB(t)minV21Upper limit valueUB(t)maxV30Current consumptionmax.ImaxA3.5Analog inputsVoltageNumber and designation7 (AI1 ... AI7)Command valueVoltageDifferential input 1UV 0 ... ±10Differential input 2UV 0+10Input resistanceRkΩ100VoltageResolution for 0...10UmV5Resolution for ± 10UmV2.5Non-linearityUmV10CurrentNumber and designation4 (AI2, AI4, AI5, AI6)Command valueCurrentImA4 … 20Input resistanceRΩ100 1)CurrentResolutionIμA5Leakage currentI0.15 (with 500 Ω between port AI x - and 0 V)1)Voltage drop at actual pressure value input with 4 mA approx. 1.7 V, wit...
GeneralComponent series1XVoltage supplyOperating voltageNominal voltageUB24 V DClower limit valueUBmin20 V DCUpper limit valueUBmax28 V DCmaximum admissible residual ripple (40…400 Hz)UPP5 V, observe the admissible limitsTotal current consumptionRunning empty: 0.2 A … 0,4 A; max. admissible load: 0.9 A … 2.6 A, external fuse protection requiredPower loss (at 24 V)WExternal fuse4 A time-lagAnalog inputs (AI)Inputs AI 1 to AI 5 1)Resolution14 bitInput AI_SV (swivel angle sensor)Number (current or voltage input via separate pin)1Resolution13 bit 1)Voltage inputs (differential inputs)Measurement range‒10 V … +10 VInput resistanceRE200 kΩ ±10 %Linearity at ...
GeneralPower supplynominal 24 V=battery voltage 21...40 V,rectified alternating voltage Ueff = 21...28 V(single-phase, full-wave rectifier)Current consumption, max.mA200Signal inputVT-MACAS-500-10/V0Ucommand: ±10 V, differential amplifierRi= 100 kΩVT-MACAS-500-10/V0/lIist: 4...20 mARsh = 200 ΩActual value signalVT-MACAS-500-10/V0Uactual: ±10 V, differential amplifierRi= 100 kΩVT-MACAS-500-10/V0/lIist: 4...20 mARsh = 200 ΩValve signalUV= ±10 V (max. 10 mA) orIV= 4...20 mA (middle 12 mA)Compensation stepcan be switched off;effective in a range of ±4 %Enable signalV=8,5...40 VError messageno error: 24 Vnom (UB) max. 50 mAerror: IN POS messageIN POS: ...
GeneralComponent series1XVoltage supplyOperating voltageUB18 to 36 VDC / max. 3.6 ACurrent consumptionMaster without axesmA500Master with axesmA800SlavemA400Analog inputsVoltage inputs (differential inputs)Input voltage, max.UEmax.+10 V to –10 V; 12 bits with 4-fold oversamplingInput resistanceRekΩ160ResolutionmV5Current inputsInput currentIemA± 20Ie4 to 20 mAInput resistanceReΩ100ReΩ500Leakage currentIvμA12ResolutionμA4Digital inputsNumber32Logic levellog 0 (low) 0 V to +5 Vlog 1 (high) +10 V to 36 VInput resistanceRe3 kΩ ±10 %Analog outputsVoltage outputsOutput voltageU±10 V PWM (pulse width modulation)Current, max.ImaxmA10Load, min.RminkΩ2Current outputsOutput current, normalizedInom...
GeneralType / versionVT-HNC100-C-3XVT-HNC100-1-3XVT-HNC100-2-3XVT-HNC100-3-3XVT-HNC100-4-3XComponent series3XVoltage supplyType / versionVT-HNC100-C-3XVT-HNC100-1-3XVT-HNC100-2-3XVT-HNC100-3-3XVT-HNC100-4-3XOperating voltage 1)UB18 to 30 VDC, residual ripple Current consumption at 24 VDCIapprox. 500 mA1 to 4 A (depending on the HNC variant and the also supplied components)1)If a 24 V encoder supply is implemented directly via the VT-HNC100...3X (supply voltage is looped in), the encoder specification has to be observed.Analog inputs (AI)Type / versionVT-HNC100-C-3XVoltage input (reference to AGND - Analog ground)Channel number1Input voltageUEmax. +12 V to –12 V (+10 V to –10 V measurable)Input resistanceRE200 kΩ ± 5 %Res...
Component series2XVoltage supplyOperating voltageUB24 VDCOperating voltageLower limit valueUB(t)minV21Upper limit valueUB(t)maxV30Current consumptionImax150 mAFuseIS4 A time-lagAnalog inputsNumber6Voltage inputsRangeU0 to 10 V or ±10 V (configurable)Input resistanceRe100 kΩ,  10 MΩ for input AI 1Resolution5 mV for range ±10 V, 2.5 mV for range 0...10 VNon-linearitymVCurrent inputsRangeI0...20 mA or 4...20 mA (configurable)Input resistanceRe100 ΩLeakage currentIv0.15 % (with 500 Ω between pin AI x- and 0 V)Resolution5 μADigital inputsSignallog 00 to 5 Vlog 116 V to UBAnalog outputsNumber3AO1 voltage outputOutput voltageU0 to 10 V or ±10 V (configur...
generalType4WRPNH.../24/C/PSize610Component series2XDesignDirectional spool valve, direct operated, with steel sleeveType of actuationProportional solenoid with position control, OBEAnschlussartPlate connection, porting pattern according to ISO 4401Installation positionAnyEarthkg2.77.5Ambient temperature range°C-20 … +50hydraulicType4WRPNH.../24/C/PSize610Maximum operating pressurebar315Maximum operating pressurePort Pbar315Port Abar315Port Bbar315Port Tbar250Maximum flowl/min100Hydraulic fluid temperature range°C-20 … +60Viscosity rangemm²/s10 … 800preferablymm²/s20 … 100Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)Class 18/16/13 according to ISO 4...
26页次1/2HomePrev12NextEnd
回到顶部
Copyright ©2005 - 2017 Siedman (Xiamen)Hydraulic Technology Co;Ltd
犀牛云提供企业云服务